Powerbackplane 3 U/6 U variant L1 P47 connector
Powerbackplane 3 U/6 U variant L1 P47 connector

 

 

Hartmann Elektronik

Powerbackplane 3 U/6 U variant L1 P47 connector

The backplanes have been designed for all CompactPCI power supply units that conform to the PICMG 2.11 Power Interface Specification and are equipped with the P47 power connector.

The backplanes are intended for mounting in a 19“ card rack with 3 U or 6 U. They can be installed directly on the card rack mounting channel.

Their installation width is 8 HP. Contiguous backplane placement in the 8 HP slot spacing is possible.

Cascading and HOT-SWAP operation have been implemented.

Hartmann backplanes are completely operable as delivered. No changes need to be made or settings to be changed by the user in the majority of cases.

Caution:

Once input power is connected, hazardous voltages may be present on the backplane.

Please observe the applicable national and international standards for handling hazardous voltages when connecting such voltages to the backplane.

On 3 U Powerbackplane:
Covers AB1 and AB2 must then not be removed. They prevent accidental contact in case of intervention by trained, qualified personnel.

Power supply connections

Two M3 screw-type terminals arranged with a spacing of 10.16 mm (.4“) are available to connect the main operating voltages of +5 V, +3.3 V and GND.
Either a cable lug or a terminal bar can be mounted on these connections. Cascaded backplanes come with a terminal bar mounted on these screw-type terminals.

Terminal bars in different lengths for loads of up to 200 A per bar are available. Please inquire.

The +12 V and –12 V auxiliary voltages are connected via M3 screwtype terminals.

Frame Ground connection X10

There is a solid electrically conductive frame GND surface in the bus boardto-card rack mounting area. An M3 screw-type terminal is used to connect the frame ground.

In smaller systems, this connection can be chosen as a star point for frame ground. Pin 1 of X0 is then also connected to the frame GND surface.
In larger systems, a suitable star point position must be located for the frame ground connection.

A capacitor (C1, C2) next to the mounting holes in each slot is standard equipment. These capacitors provide HF-coupling of CHA-GND with LOGIC-GND. A 1 MΩ resistor discharges the capacitors and electrostatic currents.

This guarantees EMC-tight mounting of the bus board on the card rack.

Current Share connectors X16 and X17

Current Share signals may be used between multiple power supplies for load balancing. These signals are not required for single power supply systems

Note:
Because implementation and timing for V1 SHARE, V2 SHARE, and V3 SHARE may vary from manufacturer to manufacturer, interoperability between two or more power supplies from different manufacturers is not guaranteed.

Jumpers

Jumper J1 connects the EN-signal (X1-27), which is connected to PS-ON (X12-14), to GND. This permits the power supply unit to be started up automatically.
If this is not desirable, jumper J1 is to be removed, and the power supply unit is to be started using external wiring.
You can either remove J1 yourself or order backplanes with the corresponding order number.

The FAL- signal of X1 is connected to FAL- of X11 und X13 via jumper J2.

Pin 8 of X12 is connected to DEG- via jumper J3.
+12 V sense is directly connected to
+12 V on the power backplane via jumper J4.

Test points

Since INH‑ is not used, pin 39 of X1 is only connected to test point TP1.
Since PRST- does not exist on connector X1, PRST- has only been run to test point TP2 on X11 and X13.
Further wiring can be implemented from there.
Since +5 V STDBY of X12 is not used, pin 9 of X12 is only connected to test point TP3.
Since -5 V of X12 is not used, pin 18 of X12 is only connected to test point TP4

Shelf enumeration switch SW1

DIP switch SW1 allows each backplane in the system to be assigned a unique logical address. Configure switches GA0-GA3 to set a unique address.

Power supply units that support the System Management Bus can pass on this information.

Set switches 1 to 3 to select the desired address.

The address set in this manner is available to the power supply unit for further evaluation. The geographic localization of equivalent components implemented by this is of great importance particularly for redundant systems in conjunction with HOT-SWAP operation.

Switch Assignments SW1

Switch
1
2
3
4

GA0
GA1
GA2
unused

Power supply Geographic Addressing

Power Supply Slot No.
GA2
GA1
GA0
1
GND
GND
GND
2
GND
GND
Open
3
GND
Open
GND
4
GND
Open
Open
5
Open
GND
GND
6
Open
GND
Open
7
Open
Open
GND
8
Open
Open
Open

Pin Assignments X1 P47 connector

V1 (typically +5 V)
V2 (typically +3.3 V)
V3 (typically +12 V)
V4 (typically –12 V)
RTN (GND)
Pin
Signal
Pin
Signal
Pin
Signal
1
V1


2
V1
3
V1


4
V1
5
RTN


6
RTN
7
RTN


8
RTN
9
RTN


10
RTN
11
RTN


12
RTN
13
V2


14
V2
15
V2


16
V2
17
V2


18
V2
19
RTN


20
V3
21
V4
22
RTN
23
Reserved
24
RTN
25
GA0
26
Reserved
27
EN-
28
GA1
29
V1ADJ
30
V1 Sense
31
GA2
32
V2ADJ
33
V2 Sense
34
S RTN
35
V1 Share
36
V3 Sense
37
IPMB_SCL
38
DEG-
39
INH-
40
IPMB_SDA
41
V2 Share
42
FAL-
43
IPMB_PWR
44
V3 Share




45
CGND
46
ACN/+DC IN








47
ACL/-DC IN

Pin Assignments

1): via jumper J3 to DEG-
2): to TP3
3): via jumper J1 to GND
4): to TP4
Pin
X0
X11
X12
X13
X14
X15
X16
X17
1
CGND
PRST-
+3.3 V
PRST-
+12 V
IPMB_SCL
V1 SHARE
V1 SHARE
2
ACN
PRST-
+3.3 V
FAL-
GND
GND
V2 SHARE
V2 SHARE
3
ACL
DEG-
GND
DEG-
GND
IPMB_SDA
V3 SHARE
V3 SHARE
4

DEG-
+5 V
+3.3 V Sense
+5 V
IPMB_PWR
unused
unused
5

FAL-
GND
+3.3 V

unused


6

FAL-
+5 V
GND Sense




7

+5 V
GND
+5 V




8

+5 V Sense
PW-OK1)
+5 V Sense




9

GND
+5 V SB2)
GND




10

GND Sense
+12 V
GND Sense




11

+3.3 V
+3.3 V





12

+3.3 V Sense
-12 V





13

GND
GND





14

GND Sense
PS-ON3)





15


GND





16 GND
17 GND
18 -5 V4)
19 +5 V
20 +5 V

Mating connector and pins (e. g.)

mating connectors to connector housing pins
Power Supply X1
(on 6 U boards)


Positronic
FC116N2-1565.0
Power Supply X0
(on 3 U boards)

AMP 350766-4
AMP 926893-1
Utility connector X11 AMP 1-215911-4


ATX connector X12
Molex 39-01-2200
Molex 39-00-0039
Utility connector X13
FCI 90311-010
FCI 77138-001
Auxiliary Power Output connector X14
TKP8851-04
TKP8851T
IPMB connector X15
Molex 51021-0500
Molex 50079-8100
Current Share connectors X16 and X17
AMP 171822-4
AMP 170204-1

Powerbackplane 3 HE/6 HE Variante L1 P47 Steckverbinder - Zubehör
Powerbackplane 3 U/6 U variant L1 P47 connector - Accessories
Fond de panier d’alimentation électrique 3 U/6 U variante L1 Connecteur P47 - Accessoires
Объединительная плата питания 3 U/6 U, модель L1 коннектор P47 - Принадлежности

F006.00225
Kabel für ATX-Stromversorgung, l = 25 cm cables for ATX power supply, l = 25 cm Câbles pour alimentation électrique ATX, l = 25 cm кабель для источника питания ATX, l = 25 см
F006.00240
Kabel für ATX-Stromversorgung, l = 40 cm cables for ATX power supply, l = 40 cm Câbles pour alimentation électrique ATX, l = 40 cm кабель для источника питания ATX, l = 40 см
F006.00255
Kabel für ATX–Stromversorgung, l = 55 cm cables for ATX power supply, l = 55 cm
Câbles pour alimentation électrique ATX, l = 55 cm кабель для источника питания ATX, l = 55 см
F006.00612
Kabel für Stromverteilungssteck-verbinder 4polig, l = 12 cm
cables for 4-pin CURRENT SHARE connector, l = 12 cm
Câbles pour partage du courant 4 broches, l = 12 cm кабель для 4-пинового
ТОКОРАСПРЕДЕЛИТЕЛЬНОГО КОННЕКТОРА, l = 12 см
F006.00845
Kabel für Utility-Steckverbinder 10polig, l = 45 cm
cables for 10-pin Utility connector, l = 45 cm Câbles pour connecteur polyvalent 10 broches, l = 45 cm кабель для 10-пинового служебного коннектора l = 45 см
F006.00945
Kabel für Utility-Steckverbinder 10/14polig, l= 45 cm
cables for 10/14-pin Utility connector, l = 45 cm Câbles pour connecteur polyvalent 10/14 broches, l = 45 cm
кабель для 10/14-пинового служебного коннектора, l = 45 см
F006.00081
Kabel für Netzanschluß über X0 für Powerbackplane Variante L1 3 HE, l = 50 cm
calbes for power supply via X0 for powerbackplane variant L1 3 U, l = 50 cm
Câbles pour alimentation électrique via connecteur X0 pour fond de panier d’alimentation électrique variante L1 3 U, l = 50 cm кабель для подачи питания через X0 для объединительной платы питания, модель L1 3 U, l = 50 см
F006.00082
Kabel für Netzanschluß „P47“, 3 Fastons 6,3 mm, l = 11 cm
cables for connector type P47, 3 Fastons 6.3 mm, l = 11 cm
Câbles pour connecteur de type P47, 3 fiches plates 6,3 mm, l = 11 cm кабель для коннектора типа P47, 3 Faston 6,3 мм, l = 11 см