Order numbers
VPX Loadboard 3 U
The VPX load test card serves to simulate loads on VPX systems. Both electrical and thermal conditions can be simulated.
The following load streams can be switched with the coding and tilt lever switches located on the front plate::
| load current | Control options | |
|---|---|---|
| 5 V |
0 A ... 15 A |
in 1 A stages |
| 12 V |
0 A ... 10 A |
in 2/3 A stages |
| 3.3 V |
0 A ... 15 A |
in 1 A stages |
| +12 V_AUX |
2/3 A |
on/off |
| -12 V_AUX |
2/3 A |
on/off |
| +3.3 V_AUX |
1 A |
on/off |
5 V must always be connected as control voltage.
Voltages are tapped at the VPX bus via the P0 and P1 plug.
Excess temperature protection
The load test card switches itself off at a temperature on the topside of the load test card or in the rack of 120 °C +-5 K.
Once cooled, it turns itself on again.
Please note:
The load test card becomes hot during operation.
The incoming voltage levels for the voltages 5 V, 12 V, 3.3 V, +12 V-AUX, -12 V-AUX and +3.3V-AUX can be measured at measuring points close to the plugs P0 and P1. These measuring points are run via the plug X1 (on the front plate).
Furthermore, 4 PTC resistors (PT100) are attached to the load test card: On the front at bottom and top and on the back at the bottom and top. It is possible to measure the temperature on the load test card or in the rack via these. These PTC resistor connections are also run via the plug X1.
Pin Assignments P0 VPX
| VS1 = 12 V, VS2 = 3.3 V, VS3 = 5 V | |||||||||
| Pin |
ROW A |
ROW B |
ROW C |
ROW D |
ROW E |
ROW F |
ROW G |
ROW H |
ROW I |
|---|---|---|---|---|---|---|---|---|---|
| 1 |
VS2 |
VS2 |
VS2 |
VS2 |
NC |
VS1 |
VS1 |
VS1 |
VS1 |
| 2 |
VS2 |
VS2 |
VS2 |
VS2 |
NC |
VS1 |
VS1 |
VS1 |
VS1 |
| 3 |
VS3 |
VS3 |
VS3 |
VS3 |
NC |
VS3 |
VS3 |
VS3 |
VS3 |
| 4 |
GND |
NC |
NC |
GND |
-12 V_AUX |
GND |
NC |
NC |
GND |
| 5 |
GND |
NC |
NC |
GND |
3.3 V_AUX |
GND |
NC |
NC |
GND |
| 6 |
GND |
NC |
NC |
GND |
+12 V_AUX |
GND |
NC |
NC |
GND |
| 7 |
NC |
NC |
NC |
GND |
NC |
NC |
GND |
GND |
NC |
| 8 |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
Pin Assignments
| NC = not connected | ||||||||||
| Pin |
P1 VPX |
X1 |
||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| ROW A |
ROW B |
ROW C |
ROW D |
ROW E |
ROW F |
ROW G |
ROW H |
ROW I |
||
| 1 |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
5V-Measuring point |
| 2 |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
-12V_AUX-Measuring point |
| 3 |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
3.3V-Measuring point |
| 4 |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
3.3V_AUX-Measuring point |
| 5 |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
12V-Measuring point |
| 6 |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
+12V_AUX-Measuring point |
| 7 |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
PTC1 Pin 1 |
| 8 |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
PTC3 Pin 1 |
| 9 |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
PTC1 Pin 2 |
| 10 |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
PTC3 Pin 2 |
| 11 |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
PTC2 Pin 1 |
| 12 |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
PTC4 Pin 1 |
| 13 |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
PTC2 Pin 2 |
| 14 |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
PTC4 Pin 2 |
| 15 |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
GND-Measuring point (connector P0) |
| 16 |
GND |
GND |
NC |
NC |
GND |
GND |
NC |
NC |
GND |
GND-Measuring point (connector P1) |
VPX-Lastprüfkarte 3 HE
VPX Loadboard 3 U
Carte de charge VPX 3 U
VPX Плата проверки нагрузки 3 U
| LXH0000521 | VPX-Lastprüfkarte 3 HE HE2664A Rev. 01 | VPX Loadboard 3 U HE2664A Rev. 01 | Carte de charge VPX 3 U HE2664A rév. 01 | Плата проверки нагрузки VPX HE2664A, версия 01 |